MS3 Products

Split Units

Ductable splits.
High wall.
Cassette unit.
Vertical Standing unit.
Floor mounted unit.
Regular high wall splits for residence & retail appliances.
The split air conditioner is one of the most widely used type of the air conditioners. Earlier window air conditioner was used most widely, but the split air conditioner is now catching up with it. The major reasons behind the popularity if split air conditioner are their silent operation and elegant looks.

Air Handling units

Double skin air-handling units.
Fan coil units.
Ceiling suspended unit.
Cassette units.
An air handler is usually a large metal box containing a blower, heating or cooling elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU.

Pumps

Primary & secondary pumps for chill water & condensing water circular
A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action. Pumps can be classified into three major groups according to the method they use to move the fluid: direct lift, displacement, and gravity pumps.
Pumps operate by some mechanism (typically reciprocating or rotary), and consume energy to perform mechanical work by moving the fluid.

Packaged Units

Package air Conditioning units
Ductable split packaging units
A package unit is the all-in-one heating and cooling system for homes

Piping & Accessories

Piping.
Fitting.
Motorized values,Balancing.
Air-Separator.
A quality joint does not only require worksite-proven welding systems, but also proper pipe preparation and the right accessories and tools.

Fans & Ventilation Systems

Basement car park ventilation.
Stair-case pressurization fans.
Exhaust fans.
Axial fans.
Propellor fans.
A fan is a machine used to create flow within a fluid, typically a gas such as air. The fan consists circulate air. Ventilation is the intentional introduction of outside air into a space.

Read More

Equipments & Accessories

DDC controls, VFD’s, VAU units, Integrations Motorized DAMPER,Fire damper, thermostat, Co, Co2 Sensors, BTU meters, values.
A power supply is an electronic device that supplies electric energy to an electrical load.supplies are designed to be secured into standard electronic equipment .

Cooling Tower

FRP forced in draft state of the air cooling tower for energy efficient operation
+ A cooling tower is a heat rejection device, which extracts waste heat to the atmosphere though the cooling of a water stream to a lower temperature.

Condensing Units

Air cooled reciprocating scroll condensing units.
In systems involving heat transfer, a condenser is a device or unit used to condense a substance from its gaseous to its liquid state, by cooling it.

Cold Rooms

Cold storage room for storage fruits, vegetables, meat, fish product.
Sericulture applications including graded cold rooms.
Diary applications.
Other specialized applications including hospital storage.
Cold Room may refer to cold store. Also known as a cool store, a warehouse the interior of which is maintained at below ambient temperature, typically well below freezing .

Clean Rooms

Clean room for hospitals.
Pharma.
Speech Assembly Halls.
Space center etc.
A cleanroom or clean room is an environment, typically used in manufacturing, including of pharmaceutical products or scientific research, with a low level of environmental pollutants such as dust, airborne microbes, aerosol particles, and chemical vapors./p>

Air-Distributer

Pre insulated ducting.
Fabricated all type of ducting.
Pumpers.
Grills.
Diffusers.
Thermal Insulations.
Acoustic Insulations.
Thermal Diffusers.
VAV etc.
Mixing systems generally supply air such that the supply air mixes with the room air so that the mixed air is at the room design temperature and humidity. In cooling mode, the cool supply air, typically around 55 °F (13 °C) (saturated) , exits an outlet at high velocity.

VRF

Variable refrigerant flow air conditioning system for energy efficient & cost efficient applications.
VRFs come in two system formats, two pipe and three pipe systems. In a heat pump 2 pipe system all of the zones must either be all in cooling or all in heating. Heat Recovery (HR) systems have the ability to simultaneously heat certain zones while cooling others.

Roof-Top Units

Roof-top package units.
Air cooled single packaged Roof Top.
An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system.

Chiller Plant

A chiller is a machine that removes heat from a liquid via a vapor-compression or absorption refrigeration cycle. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream (such as air or process water). As a necessary byproduct, refrigeration creates waste heat that must be exhausted to ambience, or for greater efficiency, recovered for heating purposes.

Exhaust Ventelation Kitchen Chimney

Kitchen ventilation is the branch of ventilation that specialises in the treatment of air from kitchens.
Kitchen ventilation presents the problems of grease, smoke and odours not usually found in other ventilation systems.
Equipment used in kitchen ventilation uses an extractor hood or canopy and a filtering system. The fan for the ventilation system may be located within the kitchen or in the duct system nearby.

Solar Sites

MSS Renewtech (A wing Under MS3) is a team of experience-rich skilled technicians & engineers joining hands with an aim to carve a niche in the retail rooftop segment of solar industry. Our USP lies in introducing premium solar components with highly skilled methods of installations both on the electrical as well as civil side at a light on the pocket cost and with a prime focus solely on the retail rooftop segment.